H401-K-FRAME-METAL-GLASS

The Glass side of the Metal Glass T Plate creates a warm and optically transparent surface perfectly flush with the microscope stage. It employes Indium Tin Oxide (ITO) coating to obtain uniform heating throughout the glass surface and a surface sensor to ensure the highest accuracy on temperature reading. The glass is chemically strengthened and protected by a rigid aluminum frame.

The metal side of the Metal Glass T Plate features a trimmed 24 mm diameter observation opening for imaging with oil immersion lenses.

The metal and glass sides have independet temperture sensors for independent temperature control of each side.

The plate is wired and must be connected to either a Bold Line Controller or a Basic Controller.

Features

  • Flush with stages with k-frame insert (160x110mm), compatible with the following XY stage: Marzhauser (all models), Ludl (all models), ASI (all models, including z-piezo), Prior H107 and H117, Leica (k-frame), Zeiss (k-frame), Olympus (k-frame)
  • Temperature range: from ambient to 60°C
  • Accuracy on specimen: ±0.3°C
  • ITO glass side thickness: 0.5 mm, chemical glass strengthening ensures highest resistance
  • Easy plate replacement, if necessary
  • Flat respect to the rest of the XY stage
H401-K-FRAME-METAL-GLASS_480x320.jpg
Glass Plate in XY Stage
 
H401-K-FRAME-METAL-GLASS-[DIMENSIONS]_420x280.jpg
Dimensions

Touch Pad Interface

Beautifully designed, simple to use and very compact.

OKO-TOUCH is all you need to operate the system.

H401-T-DUAL_420x280.JPG
H401-T-DUAL

H401-T-DUAL

Push Botton Interface

Not compatible with gas Controllers

Not compatible with gas Humidifiers

Chamber feedback mode

No Room Temperature monitoring

No External Temperature Sensor

Compatible with Objective Heater. Manual calibration

 

H401-T-DUAL-BL_420x280.JPG
H401-T-DUAL-BL

H401-T-DUAL-BL

Two independent control channels

3.2'' touch screen user interface

Data logging via RS232 and DATA LOG software

T range: from 3°C above ambient to 60°C

Self calibration routine

Dimensions: 84x125x164 mm

Temperature accuracy on the specimen: ±0.3°C, if room temperature remains within ± 1°C

Customer care is our top priority

CONTACT US

Okolab S.r.l.

FACTORY NAPOLI: Via A. Olivetti, 1 - 80078 Pozzuoli, NA, Italy

FACTORY ROVERETO: Via delle Zigherane - Edificio B08.01, 38068 Rovereto, TN, Italy

 

  • Luca Lanzaro Ph.D
  •   Phone: +39 081 8062624
  •   E-mail: info[at]oko-lab[dot]com

Okolab USA Inc.

417 Thorn St., Suite 309, Sewickley - PA 15143, USA

 

  • Lara Petrak
  • Mobile: +1 (650) 410 0756
  • Rob Davison
  • Phone: +1 (650) 228 6154
  •   E-mail: usa[at]oko-lab[dot]com

Okolab Shanghai Co., Ltd.

Room 2604, Jiande Apartment, No. 9 Jiande Road, Huangpu District, Shanghai 200025, China

 

  • Pony Tong
  • Mobile: +86 18500508458
  •   E-mail: tong[at]oko-lab[dot]cn
 

COPYRIGHT © OKOLAB S.R.L. ALL RIGHT RESERVED. CERTIFIED ISO 9001.